Critical

VMSA-2026-0008.1 — Apply KB 460732 on 9.1.1 or KB 460734 on 5.2.x, 9.0.x and 9.1.0, keep SDDC Manager reachable only from trusted admin hosts, and subscribe to the advisory so you see the patch the day it lands.

Details →

Latest News from the Web

Weekday edition · archive

It's a quiet Monday for VMware news. The newest VCF 9.1.1 patches on TechDocs are still the October set, no new VMware KBs have appeared, and the Terraform providers and Packer plugins haven't released anything. KubeCon North America opens in Salt Lake City today, so this is the week to watch for VKS news from Broadcom's booth sessions.

There's no new VMSA today. SDDC Manager is still waiting for its Brotli patch, so keep the workaround in place, especially with tomorrow's press-reported federal deadline.

Elsewhere, Channel Dive has the first real detail on how vSphere Express is sold, and the vsphere Terraform provider has a fix queued for a network lookup retry that hasn't worked since 2.14.0. Today's deep dive is on NSX tunnel endpoints in VCF 9.x: the MTU rules, sharing a VLAN between host and Edge TEPs, and the settings you can't change once an Edge is deployed.

This is an earlier briefing. Read today's Latest Tech News →

  • Security No new VMSA SDDC Manager's Brotli patch is still pending
  • Releases & KBs All quiet The newest VCF 9.1.1 patch is still from 26 Oct
  • Terraform & Packer Nothing new A vsphere network lookup fix is queued for 2.18.0
  • Next deadline 10 Nov CISA deadline for the Brotli flaw, per press

Key Takeaways

  • Urgent Keep the Brotli workaround on SDDC Manager, and get the ESX logging fix in before Wednesday. VMSA-2026-0008.1 still shows "Patch pending" for every SDDC Manager version, so KB 460732 on 9.1.1 (or KB 460734 on 5.2.x, 9.0.x and 9.1.0) is what's protecting you. Press reports put the US federal deadlines at 10 November for the Brotli flaw and 11 November for ESX CVE-2026-41709, whose fixed builds are in the VMSA-2026-0006 matrix.
  • Before upgrading Set the Edge TEP MTU in NSX's Global Fabric Settings before you build Edge clusters from vCenter. KB 422523 explains that the VCF 9 Edge workflow always uses the global fabric MTU, and changing it afterwards doesn't touch Edges you've already deployed. Get the TEP VLAN right at the same time: on VCF 9.0 and 9.0.1, KB 456147 says the only supported fix for a wrong Edge TEP VLAN is redeploying the Edge cluster.
  • This month If vSphere Express is on your shortlist for a small site, check the buying rules before you budget for it. Channel Dive reports you buy all 128 cores as one licence that can't be expanded, Broadcom approves each purchase, and only existing partners can sell it; cloudmagazin adds that several Express instances can't be managed centrally. Broadcom hasn't published a price.
  • Lab If your nested lab shares one TEP VLAN between hosts and Edges, turn on "NSX on DVPG" for the Edge cluster. Without it, KB 411992 says the Edge tunnel never comes up on VCF 9.x. Single-node NSX labs with vCenter on the same cluster can't enable it, so either scale NSX to three nodes or give the Edges their own TEP VLAN.
  • Watch Don't rely on retry_timeout in the vsphere provider's vsphere_network data source until 2.18.0 ships. Issue #2802 shows it never retries a missing network, a bug the reporter traces back to 2.14.0 and reproduces on 2.17.2. The fix in PR #2803 is approved and on the 2.18.0 milestone, which also carries the vsphere_namespace breaking change.

Security Advisories Latest four

There's no new VMSA today, so these are the four most recently released or updated advisories; Broadcom's advisory portal has the rest. VMSA-2026-0008.1 still lists "Patch pending" for every SDDC Manager version, and vCenter CVE-2026-59310 in VMSA-2026-0006 remains the most important fix if you haven't applied it. SecurityOnline's weekly round-up [Press] shows no VMware CVE was added to the CISA KEV catalogue between 2 and 8 November. Broadcom still hasn't published a statement on the OpenSSH "SSHole" flaw CVE-2026-123158, which The Hacker News [Press] reports being exploited on musl-based systems such as Alpine, or on the Linux kernel TCP flaw CVE-2026-98432.

VMSA-2026-0008.1 Critical Open Rev .1 · 28 Oct 2026

Node.js, as used in SDDC Manager, has a Brotli decoder out-of-bounds write that an attacker with network access to SDDC Manager could use to run code. It is critical (9.8) on SDDC Manager 9.1.1 and important (7.5) on 9.0.x, 9.1.0 and 5.2.x; revision .1 on 28 Oct clarified the impacted products in the response matrix. Every fixed version in the matrix is still "Patch pending", and the only SDDC Manager 9.1.1 patch on TechDocs, 9.1.1.0200, doesn't mention it. Broadcom's portfolio statement KB 460791 says SDDC Manager in VCF 9.1.1 is the only critically affected product. Press reports say CISA added the underlying Brotli flaw to its KEV catalogue on 27 Oct with a federal deadline of 10 Nov, which is tomorrow; the Broadcom advisory itself makes no statement on exploitation. Issue date 27 Oct 2026.

  • CVE-2026-111497 9.8 SDDC Manager Node.js Brotli · 9.8 on 9.1.1, 7.5 elsewhere · reported KEV 27 Oct

DoApply KB 460732 on 9.1.1 or KB 460734 on 5.2.x, 9.0.x and 9.1.0, keep SDDC Manager reachable only from trusted admin hosts, and subscribe to the advisory so you see the patch the day it lands.

VMSA-2026-0007 Critical Open Initial · 3 Sep 2026

For desktop hypervisors: Workstation 25H2 and 26H1 and Fusion 25H2 and 26H1, CVSSv3 8.1 to 9.3. Both CVEs need local admin rights inside a guest and can lead to code execution on the host. There are no workarounds and the advisory makes no statement on exploitation.

  • CVE-2026-59346 9.3 VMXNET3 integer overflow
  • CVE-2026-59347 8.1 HGFS stack overflow

DoUpdate Workstation and Fusion to 26H1u1, especially if you run nested labs on a laptop.

VMSA-2026-0006.2 Critical Exploited Open Rev .2 · 19 Aug 2026

Still the one to prioritise. It covers vCenter, ESX, Workstation and Fusion (and so VCF, VVF and Telco Cloud), CVSSv3 2.7 to 9.8, with no workarounds. CISA added vCenter CVE-2026-59310 to its KEV catalogue on 18 Aug 2026 with known ransomware use. Security Affairs [Press] reports CISA added the ESX logging flaw CVE-2026-41709 on 28 Oct with a federal deadline of 11 Nov; it has its own fixed builds in the matrix. The Broadcom advisory itself makes no statement on exploitation. First published 29 Jul 2026; revision .2 on 19 Aug added 7.0 patch guidance for the critical issues.

  • CVE-2026-59309 9.8 vCenter VMDir auth bypass
  • CVE-2026-59310 9.8 vCenter Syslog traversal · KEV
  • CVE-2026-47876 9.3 ESX VMXNET3
  • CVE-2026-41703 7.6 ESX OOB read
  • CVE-2026-41709 2.7 ESX logging · reported KEV 28 Oct

DoPatch vCenter to 9.1.0.0300, 9.0.2.0100 or 8.0 U3k / U2f (VCF 5.x: async patch to 8.0 U3k per KB 88287). On ESX 9.0, ESXi-9.0.2.0100-25595025 covers all three ESX CVEs. On 9.1 the matrix lists ESXi-9.1.0.0200-25557999 for CVE-2026-47876 and ESXi-9.1.0.0-25370933 for the other two. On 8.0, ESXi80U3k-25595708 fixes CVE-2026-47876, U3i-25205845 CVE-2026-41703 and U3j-25429389 CVE-2026-41709; ESXi80U2f-25626445 covers only CVE-2026-47876. For VCF 5.x the matrix lists 5.2.4 for CVE-2026-41709.

VMSA-2026-0005.1 Critical Open Rev .1 · 7 Aug 2026

If you run Avi Load Balancer (including for VKS or VCF Automation), this one matters. Seven CVEs, CVSSv3 7.1 to 9.8, no workarounds; the worst, CVE-2026-47865, is an authentication bypass on the Avi control plane. The advisory makes no statement on exploitation. First published 14 Jul 2026; revision .1 on 7 Aug added the 22.1.7-2p12 patch.

  • CVE-2026-47865 9.8 control-plane auth bypass
  • CVE-2026-47871 8.8 directory traversal
  • CVE-2026-47867 8.7 RCE
  • CVE-2026-47869 8.7 authenticated RCE
  • CVE-2026-47866 8.3 authorisation bypass
  • CVE-2026-47868 7.8 local privilege escalation
  • CVE-2026-47870 7.1 privilege escalation

DoUpgrade 32.1.1 to 32.1.2 or later (the advisory's recommended version), 31.1.1–31.2.2 to 31.2.2-2p3, and 30.1.1–30.2.6 to 30.2.7. On 22.1.x, 22.1.7-2p12 fixes CVE-2026-47865, but the matrix lists 30.2.7 for the other six.

All VMware security advisories on Broadcom's support portal →

KB Articles & Known Issues Nothing new

No new VMware KBs today, and the articles we follow haven't moved. KB 460791 still names SDDC Manager in VCF 9.1.1 as the only critically affected product for the Brotli flaw, with no fixed version; KB 460199 on the eMudhra certificate compromise still promises fixes "in upcoming product releases" without naming them; KB 458671 (NSX Manager 9.1.1 hanging on restart with host-based agent VM services) still offers only the proton timeout workaround; KB 452660 (NSX SCRX after a 9.0.1 to 9.1.1 upgrade) still points to an unnamed upcoming NSX version; KB 456305 (VCF Operations certificate alerts) still has a fix planned; and KB 459989 still lists zero affected VCF products for PHP2Shell. If you're about to build Edges, today's deep dive leans on three older KBs worth bookmarking: KB 422523, KB 456147 and KB 411992.

Releases & Release Notes Nothing new

No new VCF patches since 26 October. The 9.1.1.x patch index still tops out at SDDC Manager 9.1.1.0200, vCenter, ESX and NSX 9.1.1.0100, VCF Operations 9.1.1.0100, VCF Automation 9.1.1.0200 and vSAN File Services 9.1.1.0200, and the SDDC Manager patch page still has no Brotli fix. The VCF 9.1 release notes list no 9.1.2 or 9.2 line, and the async releases page has nothing new. Broadcom's ESX build numbers KB 316595 agrees: ESX 9.1.1.0100 (25782009, 12 Oct) is the newest 9.x build and 8.0 Update 3k (25595708) the newest 8.0 U3 patch.

Automation & IaC

Terraform & Packer Nothing new

No new provider or Packer plugin releases today; vcf 0.19.0 is still the one to use for VCF 9.1.1, per the README. There is movement in the repos, though.

  • vsphere provider: `retry_timeout` on `vsphere_network` never retries terraform-provider-vsphere 6 Nov Official If your pipelines create a port group and then look it up straight away, this explains intermittent "not found" failures. The reporter traces the bug to a pointer-type mismatch introduced in 2.14.0 and reproduced it on 2.17.2. The fix, PR #2803, is approved and on the 2.18.0 milestone, alongside the still-unreleased storage_policies to storage_policy breaking change on vsphere_namespace.
  • vcfa provider: new `vcfa_virtual_network_appliance_cluster` data source terraform-provider-vcfa 8 Nov Official Merged on Sunday and not yet in a release. It adds a data source for looking up virtual network appliance clusters in VCF Automation, with its acceptance test gated to VCF Automation 9.1.0; 1.2.3 is still the latest release.
  • Avi provider issue #719 is still waiting for a maintainer terraform-provider-avi 28 Oct Official On 32.1.4, removing an avi_pool's last server block still shows no plan changes and leaves the members in place. Still open with no comments, so keep checking pool membership after applies.

Automation & API Ecosystem Nothing new

A steady start to the week: vmware.vmware_rest 5.1.0 (6 Nov), vmware.vmware 2.13.0 (5 Nov), VCF.PowerCLI 9.1.1, govmomi 0.56.2 and vcf-sdk-go 0.8.1 are all still current.

Deep Dive of the Day

NSX tunnel endpoints in VCF 9.x: MTU, shared VLANs and the choices you can't undo

Tunnel endpoints (TEPs) are the VMkernel and Edge interfaces that carry NSX's Geneve overlay traffic between hosts and Edges. They're easy to set up and easy to forget, right up until a tunnel shows down or large packets quietly disappear. In VCF 9.x, a few of the decisions you make about them at deployment time are effectively permanent, so they're worth getting right first time, in production and in the lab.

Start with MTU. Broadcom's network fabric design requires the host and Edge TEP VLAN, and its first-hop gateway, to be set to 1700 or greater, and recommends 9000. Geneve will run at 1600, but Broadcom calls that out as not the recommended minimum, because it leaves too little room for future header growth. The overlay segments themselves have to be 200 bytes smaller than the TEP MTU, so a 9000-byte TEP network gives you 8800-byte segments at most. Geneve packets carry the don't-fragment flag, so anything in the path with a smaller MTU drops them rather than fragmenting. That's why jumbo frames have to be enabled end to end, including on intermediate switches and gateways.

The VCF 9 Edge workflow in vCenter adds its own twist. KB 422523 explains that it always uses the default "nsx-edge-multiple-vteps-uplink-profile", whose MTU you can't edit, because the workflow takes the Edge TEP MTU from NSX's Global Fabric Settings. Change that value after deployment and the Edges you've already built keep their old MTU. So set the Edge tunnel endpoint MTU under System > Fabric > Settings > Global Fabric Settings before you start, and check the value the wizard shows you as it runs.

VLANs deserve the same care. KB 456147 describes Faulty TEP alarms on VCF 9.0 and 9.0.1 where host-to-host and Edge-to-Edge tunnels are fine but host-to-Edge tunnels are down. The cause is an Edge TEP that kept its original VLAN after a new uplink profile was attached. The Edge TEP VLAN is set at deployment, and the only supported fix on those versions is to redeploy the Edge cluster. If you suspect it, SSH to the Edge, use get gateways to find the tunnel VRF, then vrf <ID> and get interfaces to see the VLAN it's really using.

Sharing one TEP VLAN between hosts and Edges is common in small sites and labs, and it's supported, with a condition. KB 411992 says that on VCF 9.x the Edge tunnel won't come up on a shared VLAN unless "NSX on DVPG" is enabled for the cluster hosting the Edges. You can enable it if NSX isn't a single-node deployment, or if the Edges sit on a cluster that doesn't host vCenter. A single-node NSX lab with vCenter on the same cluster has to scale NSX out to three nodes first, or simply use separate TEP VLANs for hosts and Edges. Daniel Krieger's evoila write-up is a useful picture of how the shared-VLAN design hangs together, written for NSX 4.1 rather than VCF 9: give host uplink profiles a standby uplink so a link failure can't black-hole Edge overlay traffic, remember that Edge uplink profiles don't support standby links, and keep the Edge fast-path interfaces on trunk segments.

For nested labs, the outer environment is usually what bites. Your physical or outer virtual switch has to pass frames large enough for the inner TEP MTU, so if it can't carry 9000, make sure every hop of the TEP path, gateway included, carries at least the 1700 minimum. In production, settle the TEP MTU and VLAN plan with your network team before bring-up, write the global fabric MTU into your build checklist, and treat a host-to-Edge-only tunnel failure as a VLAN or MTU question before you go looking anywhere else.

Based on Network Fabric Detailed Design (Broadcom TechDocs) Official KB 422523: Unable to change MTU on Edge fp-eth interfaces in VCF 9 Official KB 456147: Faulty TEP alarm and BFD tunnels down in VCF 9.0 Official KB 411992: Sharing the same VLAN TEP for ESXi host and Edge VM Official evoila: Sharing the overlay transport VLAN between ESXi TEPs and Edge TEPs (Daniel Krieger) Community

Industry One worth reading

Licensing, Business & Industry News One worth reading

  • Broadcom courts midmarket customers with economy-sized VMware bundle Channel Dive 6 Nov Press The first detail on how vSphere Express is actually sold. Broadcom still hasn't published a price, but TD Synnex lists a one-year 128-core bundle at $9,600; resellers quoted say you must buy all 128 cores as a single licence that can't be expanded, Broadcom approves each purchase and decides which existing customers qualify, and only existing partners can sell it.
  • Broadcom startet VMware-Einstieg für 128 Kerne cloudmagazin 7 Nov Press A German take on the same story, quoting roughly €8,500 a year. The detail that matters for multi-site designs is that several Express instances can't be managed centrally, even though their cores are counted together.

Community & Learning Latest episodes

Videos, Podcasts & Events Latest episodes

Sources (40)

Recent Briefings

Full archive → RSS

Tags: Official Broadcom and VMware sources, Press trade press, Community community posts and unverified reports.

Thanks for visiting

Let's talk tech!

Questions, ideas, or just want to talk VCF? Drop me an email or find me on the socials.

Email me →