Critical

VMSA-2026-0008.1 — Apply KB 460732 on 9.1.1 or KB 460734 on 5.2.x, 9.0.x and 9.1.0, keep SDDC Manager reachable only from trusted admin hosts, and subscribe to the advisory so you see the patch the day it lands.

Details →

Latest News from the Web

Weekday edition · archive

It's a quiet morning for patches, which makes it a good day to read Broadcom's new six-part series on tenant connectivity in VCF 9.1. If you run NSX VPCs, and especially if you've ever wondered why a VPC workload leaves with one source address on one path and a different one on another, Part 2 sets out the four rules that decide it, and today's deep dive builds on it.

Security hasn't changed, and it still needs your attention. There's no new advisory from Broadcom, but vCenter CVE-2026-59310 from VMSA-2026-0006 remains in CISA's Known Exploited Vulnerabilities catalogue with known ransomware use, so any unpatched vCenter is still the top job.

Elsewhere, three Broadcom KBs are worth a read before your next 9.1.1 upgrade, VCF Operations 9.1.1 has a new capacity forecasting engine that may nudge your rightsizing numbers, and there's a small correction on the Azure VMware Solution deadline: 31 October applies to licence-included PayGo SKUs, not every licence-included node.

This is an earlier briefing. Read today's Latest Tech News →

  • Security No new advisories Newest is VMSA-2026-0007 (3 Sep); three have CVEs in CISA KEV
  • Releases & KBs No new patches Three KBs worth reading before a 9.1.1 upgrade
  • Terraform & Packer All quiet vcf 0.19.0 is still the one for VCF 9.1.1
  • Next deadline 10 days 31 Oct: AVS PayGo licence-included SKUs retire

Key Takeaways

  • Urgent If any vCenter is still unpatched, it's still the first job of the day. CVE-2026-59310 is in CISA KEV with known ransomware use. Get every reachable vCenter, lab ones included, to 9.1.0.0300 or any later 9.1.x patch, 9.0.2.0100, or 8.0 U3k / U2f, and check VCF Operations is on 9.0.2.0 or later and VMware Tools on 13.0.5 or 12.5.4, since both carry older KEV-listed CVEs.
  • Before upgrading A few minutes of checks will save you a stuck 9.1.1 upgrade. Run the KB 455737 VUM schema check on Supervisor estates (KB 457944 still has no fixed build). If the NSX Manager precheck times out with "Resource validation timeout", KB 457342 explains the stale ACTIVATING status in SDDC Manager's inventory. And if you're on NSX 9.0.1, keep an eye out for a "Security Services Health Degraded" alarm after upgrading (KB 452660), especially if you rely on L7 rules or IDPS.
  • This month 31 October is the cut-off for AVS licence-included PayGo SKUs. Reserved-instance licence-included SKUs run until 30 August 2027, per Microsoft. Insight's North American VMware partner status also ends on 31 October, and new VCSP contracts move to VCSP Commit on 1 November.
  • Lab A distributed transit gateway is the lightest way to get VPCs talking to the outside world in a lab. You don't need Edge nodes, but the external VLAN has to reach every host on the same uplinks as the overlay vmkernel adapter, and you'll want a VNA cluster (Small is fine for a lab) if you need default outbound NAT.
  • Watch VCF Operations 9.1.1 changes how capacity is forecast. Rightsizing and time-remaining figures may shift slightly after the upgrade. Compare old and new values in /storage/log/vcops/log/capacityMetricsUpgradeChanges.csv before anyone acts on a sudden change.

Security Advisories 4 open · 3 with CVEs in CISA KEV

Nothing new from Broadcom today. The newest advisory on its Security Advisory portal is still VMSA-2026-0007 from 3 September, and every open advisory reads exactly as it did yesterday. Three older advisories have CVEs in CISA's Known Exploited Vulnerabilities catalogue, so they deserve another look if they aren't already closed out in your estate.

VMSA-2026-0007 Critical Open Initial · 3 Sep 2026

This one is for desktop hypervisors: Workstation and Fusion 25H2 and 26H1, CVSSv3 8.1 to 9.3. Both CVEs need local admin rights inside a guest, neither is in CISA KEV, and the advisory makes no statement on exploitation. First published 3 Sep 2026.

  • CVE-2026-59346 9.3 VMXNET3 integer overflow
  • CVE-2026-59347 8.1 HGFS stack overflow

DoUpdate Workstation and Fusion to 26H1u1. There's no workaround, so if you run nested labs on a laptop, it's worth doing soon.

VMSA-2026-0006.2 Critical Exploited Open Rev .2 · 19 Aug 2026

This is the one to prioritise. It covers vCenter, ESX, Workstation and Fusion (and so VCF, VVF and Telco Cloud), with CVSSv3 scores from 2.7 to 9.8 and no workarounds. CISA added CVE-2026-59310, a vCenter Syslog directory traversal, to its KEV catalogue on 18 Aug 2026 and lists known ransomware use. The Broadcom advisory itself says the issues were privately reported and makes no statement on exploitation; the other four CVEs aren't in KEV. Broadcom notes that patches are cumulative and that vCenter 9.1.0.0200 was the first release to fix CVE-2026-59309. First published 29 Jul 2026.

  • CVE-2026-59309 9.8 vCenter VMDir auth bypass
  • CVE-2026-59310 9.8 vCenter Syslog traversal · KEV
  • CVE-2026-47876 9.3 ESX VMXNET3
  • CVE-2026-41703 7.6 ESX OOB read
  • CVE-2026-41709 2.7 ESX logging

DoPatch vCenter to 9.1.0.0300, 9.0.2.0100 or 8.0 U3k / U2f (on VCF 5.x use the async patch in KB 88287; on 7.0, extended-support customers should contact Broadcom). For ESX, apply ESXi-9.1.0.0200-25557999, ESXi-9.0.2.0100-25595025, ESXi80U3k-25595708 or ESXi80U2f-25626445. If a vCenter has been reachable and unpatched, it's safest to treat it as possibly compromised.

VMSA-2026-0001.1 Important Exploited Open Rev .1 · 3 Mar 2026

Affects Aria Operations and VCF Operations, CVSSv3 6.2 to 8.1. CVE-2026-22719, a command injection, has been in CISA KEV since 3 Mar 2026. Broadcom says it "is aware of reports of potential exploitation" but "cannot independently confirm their validity". First published 24 Feb 2026.

  • CVE-2026-22719 8.1 command injection · KEV
  • CVE-2026-22720 8.0 stored XSS
  • CVE-2026-22721 6.2 privilege escalation

DoMove VCF Operations 9.x to 9.0.2.0 or later, and Aria Operations 8.x (including on VCF 4.x/5.x) to 8.18.6; Telco Cloud customers should follow KB 428241. If you can't patch straight away, KB 430349 has a workaround for CVE-2026-22719.

VMSA-2025-0015.1 Important Exploited Open Rev .1 · 30 Oct 2025

Affects Aria Operations and VMware Tools, CVSSv3 4.9 to 7.8. CVE-2025-41244, a local privilege escalation, has been in CISA KEV since 30 Oct 2025, and here Broadcom goes further, saying it "has information to suggest that suspected exploitation of CVE-2025-41244 has occurred in the wild". First published 29 Sep 2025.

  • CVE-2025-41244 7.8 local privilege escalation · KEV
  • CVE-2025-41246 7.6 Tools for Windows
  • CVE-2025-41245 4.9 info disclosure

DoUpdate VMware Tools to 13.0.5 or 12.5.4, VCF Operations 9.x to 9.0.1.0 or later, and Aria Operations 8.x to 8.18.5 (for 4.x/5.x under VCF, see KB 92148). There's no workaround, so patching is the only fix.

All VMware security advisories on Broadcom's support portal →

Corrections

  • The 31 October Azure VMware Solution deadline applies to licence-included PayGo SKUs only. Reserved-instance licence-included SKUs, and the licence-included service as a whole, run until 30 August 2027, per Microsoft; earlier briefings said all licence-included nodes had to move to VCF BYOL by 31 October.

KB Articles & Known Issues Three worth reading

None of these show an updated date, but all three are about the 9.1 to 9.1.1 upgrade path, so they're worth a read before your next maintenance window.

  • KB 457342: VCF upgrade precheck fails on the NSX Manager phase with a resource validation timeout Broadcom KB VCF 9.1.x / SDDC Manager Official If your 9.1 to 9.1.1 precheck stalls at NSX Manager planning with "Resource validation timeout" in VCF Operations, and lcm-debug.log shows NsxClusterRetrievalException: Failed to retrieve NSX-T manager, this is the likely cause. SDDC Manager's inventory has the NSX Manager cluster stuck in ACTIVATING instead of ACTIVE. The fix is to snapshot SDDC Manager, pull the cluster record from the local inventory API, change only the status to ACTIVE, PUT it back and rerun the precheck.
  • KB 452660: SCRX service may not be running after upgrading NSX from 9.0.1 to 9.1.1 Broadcom KB NSX 9.1.1 Official Rare, but worth knowing if you use L7 rules or IDPS. A race during the upgrade can start SCRX before the host's config store is ready, so it never comes up. You'll see a "Security Services Health Degraded" alarm, traffic that needs L7 classification may not be handled properly, and IDPS traffic with a drop oversubscription policy can be affected. Broadcom lists it as a known issue with no workaround and a fix in an upcoming NSX release.
  • KB 455225: SDDC Manager upgrade prechecks fail with "Triggering SDDC Manager upgrade bundle failed" Broadcom KB SDDC Manager 9.1.0.0400 to 9.1.1 Official If you're on SDDC Manager 9.1.0.0400 with management components already on 9.1.1, the precheck backend can't parse the target version string 9.1.1.0.25713928 and throws a red banner. The workaround is simply to run prechecks and plan the upgrade from VCF Operations under Build > Lifecycle > Upgrades > VCF Instances instead.
  • KB 457944: Supervisor Control Plane VMs missing after upgrading to VCF 9.1 / 9.1.1 Broadcom KB Still open Official Still waiting on a fix. The resolution still reads "The issue is fixed in the next release of VCF 9.1.1" without naming a build. Until then, run the KB 455737 VUM schema checker before any vCenter 9.1.x upgrade on Supervisor or VKS estates; if the VMs have already gone, recovery means reverting vCenter and restoring the Supervisor from backup.

Releases & Release Notes Nothing new

Another quiet day for release notes. Nothing has landed for VCF, vSphere, NSX or vSAN since the 9.1.1 patch batch on 12 October, so the builds in the side panel are still current.

  • VCF 9.1 release notes index Broadcom TechDocs Last updated 19 Oct Official The newest dated entry is still "New patches for 9.1.1 components" from 12 Oct, and there's no sign yet of a 9.1.2 or 9.2 line. The Async Releases page is unchanged too, still listing VMware Tools 13.1.0, VMRC 13.1, the vSphere Container Storage Plug-in 3.0, VCF Operations for Integrations 9.1.1 and the VKS, VKr and VKS add-on notes.
  • VMware vSphere Kubernetes Service release notes Broadcom TechDocs Last updated 8 Oct Official VKS 3.7 is still the newest line, with 3.7.2+v1.36 (8 Oct) the current release, so there's nothing new to stage before a Supervisor upgrade this week.

Automation & IaC

Terraform & Packer Nothing new

Nothing new from the providers or Packer plugins today. The vcf provider README still lists VCF 9.1.1 support from v0.19.0, which shipped on 7 Oct and is still marked Latest on GitHub. Every current version and the full support table are in the side panel.

  • terraform-provider-vcfa v1.2.3 GitHub 26 Sep Official Still the latest VCF Automation provider, and a nice quality-of-life release: vcfa_vks_cluster can now change cluster_class.name in place (a ClusterClass rebase), so you can upgrade cluster_class and version in a single apply (#258). Changing cluster_class.namespace still forces a replacement. It also fixes a ModifyPlan panic (#255) and perpetual drift on os_image.version (#257).
  • Packer plugins: vsphere 2.5.0 and vmware 2.1.6 GitHub 31 Aug Official Both are still the latest releases (see also the vmware plugin). One thing to watch: vsphere 2.5.0 removed vTPM support, so any templates that relied on it will need another approach.

Automation & API Ecosystem All quiet

Nothing to update this week. VCF.PowerCLI 9.1.1.25718932 (10 Sep) is still the current version on the PowerShell Gallery, and govmomi v0.56.0 (21 Aug) is still the latest release.

Nested Lab Corner

  • VCF 9.1 Home Lab Series Part 14: Distributed Transit Gateway for VPCs vStellar (Manish Jha) 31 Jul Community A handy companion to today's deep dive if you want to try VPC external connectivity at home. Two lab lessons stand out: the auto-created connectivity profile has no private transit gateway block, so cross-VPC traffic won't work until you add one, and the external IP block has to sit inside the distributed VLAN connection's CIDR.
  • Holodeck 9.1 GitHub (vmware/Holodeck) May 2026 Official Still the newest Holodeck release, supporting VCF 9.1.0.0, 9.0.0 to 9.0.2 and 5.2 to 5.2.4. There's still no 9.1.1 build, so a 9.1.1 lab means building it yourself.
Deep Dive of the Day

VPC transit gateways and external connections in VCF 9.1

If you've started using NSX VPCs in VCF 9.1, the part that usually takes longest to click is how a VPC actually reaches the outside world. Broadcom's model has three layers. A VPC is an on-demand logical network inside an NSX project. Every project, including Default, gets a transit gateway that joins its VPCs together and links them outwards. And the transit gateway attaches to one or more external connections, which are the real links into your physical network. A VPC Connectivity Profile glues it all together: it names the transit gateway, the IP blocks the VPC may use, and whether Default Outbound NAT is switched on.

There are three kinds of external connection, and your choice shapes everything else. A centralised connection goes through a Tier-0 gateway on NSX Edge nodes, which gives you BGP with the fabric and stateful services, and lets you configure NAT on the transit gateway. A distributed VLAN connection skips Edges entirely and connects the transit gateway straight to fabric VLANs on the ESX hosts, with stateful services coming from Virtual Network Appliances (VNAs). From 9.1.1 there's also a distributed VXLAN connection for EVPN fabrics, again using VNAs for advanced services. Attaching a transit gateway to a centralised connection makes it a centralised transit gateway (CTGW); attaching it to a distributed one makes it a distributed transit gateway (DTGW).

A few rules from TechDocs are easy to trip over. All the external connections on one transit gateway must be the same type, so you can't mix centralised and distributed. A VPC connects to only one transit gateway at a time, although you can move it by changing its connectivity profile, and NSX runs IPAM and span checks when you do. Public subnets and external IPs can't overlap across different DTGWs. And a CTGW can now run its own HA mode on an Edge cluster that differs from the Tier-0's: active-active suits throughput, active-standby suits NAT. That fixes the old limitation where an active-active Tier-0 meant no auto SNAT, and sharing the Tier-0's HA mode is now deprecated.

Then there's the question of which source address a packet leaves with, which Part 2 of the new VCF blog series answers neatly. Public subnets come from external IP blocks and are routed as they are. Private-VPC subnets only get out through NAT. Private-TGW subnets can talk to other VPCs on the same transit gateway without NAT, but need NAT at the CTGW or explicit advertisement to leave. Default Outbound NAT applies first (at the VPC gateway for Private-VPC, at the CTGW for Private-TGW), the CTGW routing table then picks the exit by longest prefix, and the exit connection either applies Provider Outbound SNAT, passes the address through, or forwards advertised Private-TGW traffic. If the source isn't authorised on that exit connection, there's no return path, and that's the failure the series sees most.

For production, decide early whether you need dynamic routing and centralised stateful services (centralised connections, Edges and a CTGW) or would rather keep things light and host-based (distributed connections and VNAs). Plan your IP blocks before you build anything, because overlaps between external blocks, VLANs, public and private subnets and transit gateway blocks cause failures that look like misconfiguration. Remember that stateful gateway firewalling on VPCs needs a vDefend licence. If you use VNAs, size them properly: community testing describes Small (2 vCPU, 4 GB) as lab-only and Large (8 vCPU, 32 GB) for production, with services running active/standby rather than active/active.

In a nested lab, the distributed VLAN route is usually the easiest win, since there's no Edge cluster to feed. The external VLAN has to be present on the hosts' uplinks alongside the NSX overlay vmkernel adapter, which in practice means a Layer 2 design where every host can reach it. Watch for the auto-created connectivity profile having no private transit gateway block (add one if VPCs need to talk to each other), keep the external IP block inside the distributed connection's CIDR, and add a small VNA cluster if you want Default Outbound NAT. It's also worth testing vMotion and a host failure, not just steady-state pings, before you trust the design.

Based on Transit Gateways (TechDocs, VCF 9.1) Official External Connections (TechDocs, VCF 9.1) Official Virtual Private Cloud in NSX (TechDocs, VCF 9.1) Official Tenant Connectivity on VCF 9.1, Part 2 (VCF blog, 20 Oct) Official VCF 9.1 – VNA and VPCs (SDN-Warrior, 11 May) Community VCF 9.1 Home Lab Series Part 14 (vStellar, 31 Jul) Community

Industry

Features & Technical Blogs

  • Tenant Connectivity on VCF 9.1 (Parts 1–6) VCF blog (Mohammad Saad) 20 Oct Official A proper reference series for anyone designing VPC networking, written for cloud providers but just as useful in an enterprise. Part 2 is the one to read first: it explains public, Private-VPC and Private-TGW subnets, Default Outbound NAT, Provider Outbound SNAT and Private-TGW advertisement, and points out that a source address not authorised on the exit connection has no return path, which it calls the most common failure. Parts 3 to 5 work through real use cases, and Part 6 covers choosing a design and running it in production.
  • A Smarter, More Transparent Way to Forecast Capacity in VMware Cloud Foundation 9.1.1 VCF blog (Kelcey Lemon) 20 Oct Official Worth knowing before your capacity reports change under you. VCF Operations 9.1.1 swaps its multi-model approach for one time-decay weighted linear regression, using up to 90 days of history (7 days for Workload Placement), separate upper and lower bounds, and a flat-trend fallback when there's under 7 days of data or a negative trend. After upgrading, /storage/log/vcops/log/capacityMetricsUpgradeChanges.csv shows what changed, and you can reset a workload's baseline after a migration using the suggested Recommended Reset Date.

Community & Learning

Community Picks

  • VPC packet flow in VCF 9.1 – all in one, drawn Marc Huppert (VCDX #181) 16 Oct Community A drawn walk-through of how a packet travels in VCF 9.1, from a VCF Automation namespace all the way down to the vmnic and the top-of-rack switch, credited to Maciej Losek. It pairs nicely with the tenant connectivity series if you think better in diagrams.
  • My Inventory – Part 2: NSX ALB, vCloud, Veeam, Proxmox, Hyper-V and the Site Scanner ProVirtualzone (Luciano Patrão) 18 Oct Community The second part of Luciano's inventory tool series moves beyond vSphere to NSX Advanced Load Balancer, Cloud Director, Veeam, Proxmox and Hyper-V, plus a site scanner. Useful if you're documenting a mixed estate ahead of a VCF 9 migration.

Videos, Podcasts & Events Three podcasts and the Explore calendar

Sources (39)

Recent Briefings

Full archive → RSS

Tags: Official Broadcom and VMware sources, Press trade press, Community community posts and unverified reports.

Thanks for visiting

Let's talk tech!

Questions, ideas, or just want to talk VCF? Drop me an email or find me on the socials.

Email me →